Panasonic F2 Type Mid Static Ducted 4.5kW VRF FSV Indoor Units
S-45MF2E5A
The new F2 type is designed specifically for applications requiring fixed square ducting. An anti-mould filter is equipped as standard.
F2 Type Mid Static Ducted 4.5kW VRF FSV Indoor Units
Variable external static pressure control
Industry-leading low sound levels from 25dB (A)
Built-in drain pump provides 702mm lift
Easy to install and maintain
Air off sensor avoids cold air drafts during heating operation
Configurable air temperature control
Anti-mould washable filters included
Variable External Static Pressure Control
Optimal airflow set-up is possible depending on ducting design and conditions.
System Example
An inspection port (450mm x 450mm or larger) is required at the lower side of the indoor unit body.
More Powerful Drain Pump
Using a high-lift drain pump, drain piping can be elevated up to 702mm from the base of the unit.
Discharge Air Temperature Control
• Possible to control discharge air temperature for accurate room temperature control.
• Possible to reduce cold drafts during heating operation.
V-Shaped Heat Exchanger
To improve heat exchange efficiency, an original V-shaped heat exchanger was developed incorporating a conventional high-efficiency slit fan and high-efficiency grooved heat transfer tubes. This increases the heat exchange surface area.
- Self-diagnosing Function
- Automatic Fan Operation
- Mild dry
- Automatic Restart Function
- Built-in Drain Pump
Industry-leading low sound levels from 25dB (A)
Built-in drain pump provides 702mm lift
Easy to install and maintain
Air off sensor avoids cold air drafts during heating operation
Configurable air temperature control
Anti-mould washable filters included
Variable External Static Pressure Control
Optimal airflow set-up is possible depending on ducting design and conditions.
System Example
An inspection port (450mm x 450mm or larger) is required at the lower side of the indoor unit body.
More Powerful Drain Pump
Using a high-lift drain pump, drain piping can be elevated up to 702mm from the base of the unit.
Discharge Air Temperature Control
• Possible to control discharge air temperature for accurate room temperature control.
• Possible to reduce cold drafts during heating operation.
V-Shaped Heat Exchanger
To improve heat exchange efficiency, an original V-shaped heat exchanger was developed incorporating a conventional high-efficiency slit fan and high-efficiency grooved heat transfer tubes. This increases the heat exchange surface area.
- Self-diagnosing Function
- Automatic Fan Operation
- Mild dry
- Automatic Restart Function
- Built-in Drain Pump
Specification
- Weight (kg)
- 29
- Refrigerant Pipe Diameter - Liquid Side / Gas Side (mm)
- 6.35 / 12.70
- Dimensions - H X W X D (mm)
- 290 x 800 x 700
- Sound Pressure Level (H/M/L) - Cooling DB(A)
- 34 / 32 / 28
- Air Flow Rate (H/M/L) - L/s
- 267 / 250 / 220
- Heating Capacity (kW)
- 5.0
- Cooling Capacity (kW)
- 4.5
- Model
- S-45MF2E5A