Panasonic Under Ceiling Split System Inverter Reverse Cycle 12.5Kw
Indoor S-125PT2R5 Outdoor U-125PE1R5/8
Choose a Panasonic Inverter Under-Ceiling Air Conditioner. Ideal for a business or large family home with no or limited wall space. Cools up to 120m2. Controller not included.
Under Ceiling Split System Inverter Reverse Cycle 12.5Kw
Compact Looking, Stylish Design. With its streamlined form, the unit looks thin and compact when instaled for a neat appearence in any room. When not operating, the louver closes to provde an elegant look while also keeping the unit clean.
Energy Saving Technology Deivering Top - Class Efficiency. Optimsiation of the shape of the casing and fan provides greater air flow and higher effciency. Energy - saving performance is among the best in the industry. A DC fan motor is also used to maximise energy savings.
Comfortable, Long - Distance Air Flow Distribution. The shape of the outlet has been optimised to provide long - distance air flow distribution. Even in long rooms, air flow reaches every corner for exceptionally comfortable air conditioning
Energy Saving Technology Deivering Top - Class Efficiency. Optimsiation of the shape of the casing and fan provides greater air flow and higher effciency. Energy - saving performance is among the best in the industry. A DC fan motor is also used to maximise energy savings.
Comfortable, Long - Distance Air Flow Distribution. The shape of the outlet has been optimised to provide long - distance air flow distribution. Even in long rooms, air flow reaches every corner for exceptionally comfortable air conditioning
Specification
- Operation Ranges
- Cooling/Heating -15 to 46 : -20 to 24
- Refrigerant At Shipping, Additional Gas Amount
- R410A 3,400, 50(g/m)
- Maximum Chargeless Length
- 30m
- Elevation Difference (OU Located Lower, OU Located Higher)
- 15,30 m
- Pipe Length
- Min-max 5-75 m
- Piping Connections
- Liquid/Gas (mm) 09.52/015.88
- Sound Pressure Level Outdoor Unit (H/M/L)
- Cooling/Heating 53/53
- Sound Power Level - Outdoor - (dB(A))
- Cooling/Heating 70/70
- Air Volume - Outdoor - Cool/Heat (L/s)
- 2,166/1,833
- Net Weight Outdoor Unit
- 98kg
- Dimensions Outdoor Unit (H X W X D)
- 1,416 x 940 x 340
- Current (Outdoor Unit)
- Cooling/Heating 16.4/15.4 | 15.8/14.9
- Drain Pipe Size
- VP-20
- Number Of Fan Speeds
- 3
- Sound Power Level - Indoor (H/M/L)
- Cooling/Heating 64/58/54 : 64/58/54
- Sound Pressure Level - Indoor - H / M / L (dB(A))
- Cooling/Heating 46/40/36 : 46/40/36
- Air Volume - Indoor (L/s)
- 566:566
- Net Weight Indoor Unit
- 40kg
- Dimensions Indoor Unit (H X W X D)
- 235 x 1,590 x 690 mm
- Current (Indoor Unit)
- Cooling/Heating 0.86:0.86 | 0.83:0.83
- Total Power Input
- Cooling/Heating 3.73 - 3.51 kW
- EER : COP
- Cooling/Heating W/W 3.35/3.99
- Heating Capacity (BTU/h)
- 47,800 (14,000 - 54,600)
- Cooling Capacity (BTU/h)
- 42,700 (11,300 - 47,800)
- Heating Capacity
- 14.0 (4.1 - 16.0)kW
- Cooling Capacity
- 12.5 (3.3 - 14.0) kW
- Power Source
- 1 Phase/ 50Hz, 230V|240V