Daikin Super Multihead Condensor Unit 5.2Kw
3MXS52LVMA
Connectable to up to 3 indoor units, the Outoor Unit Quiet Operation and Night Quiet Mode features of the 3MXS52EVMA will keep your home comfortable all year round.
Super Multihead Condensor Unit 5.2Kw
3MXS52EVMA
Super Multi outdoor units feature Outdoor Unit Quiet Operation and Night Quiet Mode. Pushing the QUIET button on the wireless remote controller decreases ouotdoor unit operation sound by 3dB from the rated operation sound.
Nightime operation sound for the outdoor unit is automatically decreased by 3dB from the rated outdoor sound. This function is available for cooling operation only.
Night Quiet Mode starts automatically when the outdoor temperature has dropped by 6°C from the maximum temperature recorded during the day.
Priority-Room Setting
When this function is set, it is convenient for selecting Inverter Powerful Operation, Outdoor Unit Silent Operation and operation mode. Initial setting is required during installation.
Night Quiet Mode
Outdoor unit operating sound levels are automatically decressed by 3dB from the rated operation sound when the outdoor temperature has dropped by 6°C from the maximum temperature recorded during the day.
Outdoor Unit Quiet Operation
Daikin's new "Outdoor Unit Silent Operation" function cuts operating sound levels for the outdoor unit by 2dB, simply by pushing a button.
Self Diagnosis
In the event that a problem develops with the unit, malfunction codes are displayed on the liquid crystal panel of the remote controller for fast and easy maintenance.
Anti-Corrosion
The special anti-corrosion coating on the outdoor unit heat exchanger ensures greater resistance to salt damage and atmospheric pollution.
Unit 3MXS52EVMA
Casing Colour Ivory White
Dimensions(H x W x D)
Outdoor(mm)735 x 936 x 300
Weight Outdoor(kg)49
Power Supply 1 phase, 230-240V, 50Hz
Compressor Type Hermetically sealed swing type
Refrigerant Type R410A
Maximum Pipe Length (m)50 (total)(m)25 (for each room)
Necessity of Additional Charge
g/m 20 (for 30m or more)
Maximum Level Difference (m)15 (between indoor and outdoor units)
Operating Range (Outdoor Temp)
Cooling CDB-5 to 46
Heating CWB-15 to 15.5
Outdoor Sound Level
Cool(dBA)46/43
Heat(dBA)47/44
Necessity of additional charge
kg/m 20 (for 30m or more)*2
Super Multi outdoor units feature Outdoor Unit Quiet Operation and Night Quiet Mode. Pushing the QUIET button on the wireless remote controller decreases ouotdoor unit operation sound by 3dB from the rated operation sound.
Nightime operation sound for the outdoor unit is automatically decreased by 3dB from the rated outdoor sound. This function is available for cooling operation only.
Night Quiet Mode starts automatically when the outdoor temperature has dropped by 6°C from the maximum temperature recorded during the day.
Priority-Room Setting
When this function is set, it is convenient for selecting Inverter Powerful Operation, Outdoor Unit Silent Operation and operation mode. Initial setting is required during installation.
Night Quiet Mode
Outdoor unit operating sound levels are automatically decressed by 3dB from the rated operation sound when the outdoor temperature has dropped by 6°C from the maximum temperature recorded during the day.
Outdoor Unit Quiet Operation
Daikin's new "Outdoor Unit Silent Operation" function cuts operating sound levels for the outdoor unit by 2dB, simply by pushing a button.
Self Diagnosis
In the event that a problem develops with the unit, malfunction codes are displayed on the liquid crystal panel of the remote controller for fast and easy maintenance.
Anti-Corrosion
The special anti-corrosion coating on the outdoor unit heat exchanger ensures greater resistance to salt damage and atmospheric pollution.
Unit 3MXS52EVMA
Casing Colour Ivory White
Dimensions(H x W x D)
Outdoor(mm)735 x 936 x 300
Weight Outdoor(kg)49
Power Supply 1 phase, 230-240V, 50Hz
Compressor Type Hermetically sealed swing type
Refrigerant Type R410A
Maximum Pipe Length (m)50 (total)(m)25 (for each room)
Necessity of Additional Charge
g/m 20 (for 30m or more)
Maximum Level Difference (m)15 (between indoor and outdoor units)
Operating Range (Outdoor Temp)
Cooling CDB-5 to 46
Heating CWB-15 to 15.5
Outdoor Sound Level
Cool(dBA)46/43
Heat(dBA)47/44
Necessity of additional charge
kg/m 20 (for 30m or more)*2
Specification
- Max Installation Height Difference
- 15 (between indoor and outdoor units) / 7.5 (between indoor units)
- Necessity Of Additional Charge
- 20 (for 30m or more)
- Max Pipe Length
- * Total 50m * Per room 25m
- Operation Range
- * Cooling -5 to 46 * Heating -15 to 15.5
- Weight
- 49 kg
- Dimensions (H X W X D)
- 735x936x300 (mm)
- Sound Power Level
- * Cooling (dBA) 59 * Heating (dBA) 60
- Sound Level
- * Cooling (dBA) 46/43 * Heating (dBA) 47/44
- Refrigerant Type
- R410A
- Compressor Type
- Hermetically sealed swing type
- Casing Colour
- Ivory White
- Max Connected Indoor Units Capacity
- 9.0 kW
- Power Supply