Fujitsu 14kW Slim Line Ducted Inverter Reverse Cycle Air Conditioner

Fujitsu Indoor ARTG54LDTA Outdoor AOTG54LBTA

High static allows more air ducts to be installed Slim and compact in design with Optional MyAir 5 zone control allowing for 10 zones.

14kW Slim Line Ducted Inverter Reverse Cycle Air Conditioner

Designed for small roof cavities, the New Fujitsu Ducted Air Conditioning Range is ideal for Brisbane homes which have a scillion roof design. This system can be retrofitted into a new build or easily fitted into an existing Brisbane home if air conditioning is required with easier options than the standard size unit.

You have the comfort of a 5-year warranty on the air conditioning manufacturer, Fujitsu Air Conditioning, and a 5-year warranty on the Advantage Air Zone Control systems in Brisbane. Aussie Air Conditioning Brisbane supplies the most comprehensive air conditioning systems and zone controls. These include Advantage Air Brisbane, Zone 10e and MyAir 5 Zone Control.

With air conditioning there can be huge temperature discrepancies between rooms, depending on their orientation to the sun and whether they are upstairs or downstairs. With MyAir 5, you can manually send more air to hotter rooms. If you prefer everything to be adjusted automatically, you have the option of upgrading to Independent Temperature Control (ITC). Each ITC sensor is like a thermostat, giving you individual room temperature control. They instruct the system to continually adjust the airflow to maintain your selected temperature. As ITC sensors ensure you won't be over air-conditioning rooms, they have the added bonus of saving energy. Sensors can be installed in as many rooms as you like, either at the time of installation or later on.

Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.

Sleep Timer
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.

ON-OFF Timer
ON-OFF timer can be set to operate once every 24 hours.

Blue Fin Heat Exchanger
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.

Fresh air intake
Fresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts). *Selected ducted units only

Weekly Timer
Different on-off times can be set for up to 7 days.

Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.

Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.

Control Port
External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.

ALL DC
With All DC, electricity loss is decreased and power consumption reduced.

Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.

Connectable Fresh Air Duct
Allows introduction of fresh air to occupied space.

Specification

Model No. - Indoor
ARTG54LDTA
Model No. - Outdoor
AOTG54LBTA
Reverse Cycle System
YES
Cooling Capacity (Watts)
14,000
Cooling Capacity (BTU/h)
47,800
Range (Watts)
6,200 — 15,200
Range (BTU/h)
21,200—51,900
Heating Capacity (Watts)
16,000
Heating Capacity (BTU/h)
54,600
Range (Watts)
6,200 — 18,000
Range (BTU/h)
21,200 — 61,500
Power Supply (Volts)
240
Phase-Frequency (Ph - Hz)
50
Power Supply Attachment
Outdoor Unit
Running Current, Cooling (Amps)
18.1
Running Current, Range (Amps)
(Maximum) - 23.5
Input, Cooling (Watts)
4,310
Input, Range (Watts)
(Maximum) - 5,600
Running Current, Heating (Amps)
17.7
Running Current, Range (Amps)
(Maximum) - 23.5
Input, Heating (Watts)
4,210
Input, Range (Watts)
(Maximum) - 5.59
Moisture Removal (l/hr)
1.8
E.E.R. - Cooling
3.25
C.O.P. - Heating
3.80
Fan Speed
4
Air Circulation, High (l/s)
1,014
Compressor Type
Twin Rotary × 1
Dimensions - Inside Unit (HxWxD Mm)
360 × 1,400 × 850
Weight - Inside Unit (kg)
69
Dimensions - Outside Unit (HxWxD Mm)
1,290 × 900 × 330
Weight - Outside Unit (kg)
93
I.U. Sound Pressure Level (dBA@1mtr)
41
O.U. Sound Pressure Level (dBA@1mtr)
57
O.U. Sound Power Level (dBA)
70
Refrigerant Type
R410A
Connection Pipe Sizes, Gas (mm)
15.88
Connection Pipe Sizes, Liquid (mm)
9.52
Pre Charged Length (Metre)
30
Minimum Pipe Length (Metre)
5
Maximum Pipe Length (Metre)
75
Maximum Pipe Height (Metre)
30
Pipe Connection Methods
Flare
Outdoor Operating Temp, Cooling Degrees C
-15 to 46
Outdoor Operating Temp, Heating Degrees C
-15 to 24
» Air Conditioning Online Catalogue

Online Catalogue

Choose from a range of top brands
and best prices.

» Air Conditioning Specialist

Air Conditioning Specialist

Talk with a knowledgeable
specialist before you buy.

» Air Conditioning Service + Support

Service + Support

We're here to help,
Let us make it easy for you.